TCR509Technical DataOperating InstructionsFUNKUHRENIncl. Software TCRMON

Strany 2 - Impressum

10The DCF Simulation ModeIn DCF-Simulation mode the TTL and current loop outputs provide a time mark signalsimilar to the signals transmitted by the g

Strany 3 - Table of Contents

11Updating the FirmwareWhenever it is necessarry to upgrade the on-board software, the new firmware can bedownloaded using the serial port COM0.If the

Strany 4

12SpecificationsSignal Input: potential freeImpedance 50Ohms also available 600 OhmsAmplitude: abt. 600mV...8V peak to peak (Mark)Supported Time Codes

Strany 5 - Introduction

13Serial modes: per second or on requestFormat of serial time string: Meinberg Standard TelegramConnectors: 64 Pin VG-ConnectorCoax RF-Connector (SMB)

Strany 6 - ATTENTION !

14Format of the Meinberg Standard Time StringThe Meinberg Standard Time String is a sequence of 32 ASCII characters starting withthe STX (start-of-tex

Strany 7 - IRIG-Mode

15Rear Connector Pin AssignmentsName Pin DescriptionGND 32a+c GroundVCC in (+5V) 1a+c +5V Supply VoltageP_SEC out 6c PPS-Signal, TTL-Level, length 200

Strany 8 - Serial Port Configuration

16Pin Assignmentac1 VCC in (+5V) VCC in (+5V)234/BOOT56 /P_SEC P_SEC78910 Reserve111213141516 GEN_OUT3- GEN_OUT3+17 GEN_OUT4- GEN_OUT4+1819 TIME_SYN2

Strany 9

17Diskette with Software TCRMON

Strany 10 - TIME_SYN Output

18The Program TCRMON.EXEThe program TCRMON was designed to monitor and control all functions of theMeinberg IRIG-Time Code Reader TCR509. TCRMON is ex

Strany 11

19The Main WindowThe main window provides an overview of all essential data like time, date, etc.Time,Date,Weekday: Show time, date and day of week. T

Strany 12 - Specifications

ImpressumWerner MeinbergAuf der Landwehr 22D-31812 Bad PyrmontTelefon: 0 52 81 / 9309-0Telefax: 0 52 81 / 9309-30Internet: http://www.meinberg.deEmail

Strany 13 - CE Label

20Setting the local Offset from UTCThe Timecode receiver TCR509 is able to re-calculate UTC from the received IRIG-Time, on condition that there are t

Strany 14

21Menu HelpThis window shows information about the current release of TCRMON and the systemressources.

Strany 16 - Pin Assignment

Table of ContentsImpressum ... 2Introduction ...

Strany 18 - The Program TCRMON.EXE

5IntroductionIn the early 1950's the use of coded timing signals for correlation of data began to takeon widespread importance. Especially the U.

Strany 19 - The Main Window

6FunctionThe received IRIG telegram is used for synchronization of software clock andbuffered real time clock. Every received telegram is checked for

Strany 20

7Setting into operationTo obtain a correct operation of the TCR509, please pay attention to the followingpoints.Supply VoltageThe board only needs a s

Strany 21 - Menu Help

8Serial Port ConfigurationBaudrate and framing for each of the both serial ports can be configured seperately bythree dip switches.SW1-1 SW1-2 Baudrat

Strany 22

9Operating mode of the serial portsEach of the two serial ports is configurable separately for two operating modes. If the 'persecond' mode