Strany 1 - GPS170LCD-MP

Technical InformationOperating InstructionsGPS170LCD-MPIncl. Windows SoftwareGPSMON32

Strany 2

10Time Zone and Daylight SavingGPS system time differs from the universal time scale UTC (Universal Time Coordi-nated) by the number of leap seconds w

Strany 3 - Table of Contents

11Time Capture InputsTwo time capture inputs called User Capture 0 and 1 are provided at the rear connector(CAP0 and CAP1) to measure asynchronous tim

Strany 4

12DCF77 EmulationThe GPS170 satellite controlled clock generates TTL level time marks (active HIGH)which are compatible with the time marks spread by

Strany 5

13Programmable pulse (optional)At the male connector Typ VG64 there are three programmable TTL outputs (ProgPulse 0-2), which are arbitrarily programm

Strany 6

14InstallationPower SupplyThe power supply used GPS170_LCD_MP see "Technical Appendix" at the end ofthis manual.Mounting the AntennaThe GPS

Strany 7 - General Information

15Antenna Short-CircuitIn case of an antenna line short-circuit the following message appears in the display:ANTENNA SHORT-CIRCUIT DISCONNECT POWE

Strany 8 - GPS170 LCDMP

16Assembly with CN-UB/E (optional)Optional the overvoltage protector CN-UB/E is available. Standard you connect theantenna converter directly with the

Strany 9 - GPS170 Features

17Powering Up the SystemIf both the antenna and the power supply have been connected the system is ready tooperate. About 10 seconds after power-up th

Strany 10 - Time Zone and Daylight Saving

18The Front Panel LayoutFAIL LEDThe FAIL LED is turned on whenever the TIME_SYN output is low (receiver is notsynchronized).LOCK LEDThe LOCK LED is tu

Strany 11 - Time Capture Inputs

19NEXT KeyWhen editing parameters (LCD cursor is visible) this key moves the cursor to the nextdigit rsp. to the next parameter to be edited. If the c

Strany 12

ImprintMeinberg Funkuhren GmbH & Co. KGLange Wand 9D-31812 Bad PyrmontPhone: +49 (0) 52 81 / 9309-0Fax: +49 (0) 52 81 / 9309-30Internet: http://ww

Strany 13 - Abstract

20"...(drft)" The frequency is generated and the phase was already syn-chronous to the pulse output P_SEC, but in the moment thep

Strany 14

21Menu RECEIVER POS.This menu shows the current receiver position. The NEXT key lets the user select oneof three formats. The default format is geogra

Strany 15 - Antenna Short-Circuit

22Menu SV POSITIONThis menu gives information on the currently selected satellite (SV). The satellite´s IDnumber, its elevation, azimuth and distance

Strany 16 - Meinberg

23SETUP FREQUENCY OUTPUT (optional)This setup menu lets the user edit the frequency and phase to be generated by the on-board synthesizer. Frequencies

Strany 17 - Powering Up the System

24SETUP ENABLE OUTPUTSThis menu lets the user configure at which time after power up the serial ports, pulseoutputs, and frequency synthesizer output

Strany 18

25SETUP DAYLIGHT SAV ON/OFFThe two topics let the user enter the range of date for daylight saving to be in effect.Concerning parameter input both top

Strany 19

26DAYLIGHT SAV ON Date: 26.03.2000Day Of Week: *** Time: 2:00:00DAYLIGHT SAV OFF Date: 26.03.2000Day Of Week: *** Time: 2:00:00DAYLIGHT

Strany 20 - REV:1.xx LCD_2

27SETUP SERIAL STRING TYPEThis topic is used to select one of several different types of serial time strings or thecapture string for each serial port

Strany 21

28SETUP SERIAL STRING MODEThis menu lets the user select the serial ports´ mode of operation. The possible modesdepend on the selected output string.

Strany 22

29Timer modePOUT x MODE: POUT TIMER AKT.: High TIME 1(-3)Time 1 ON : 10:50:00 OFF: 11:00:00Time 2 ON :

Strany 23 - Phase: +90.0°el

Table of ContentsImprint ... 2General Information ...

Strany 24

30Cyclic modeCyclic mode is used for generating periodically repeated pulses.POUT x MODE: CYCL. PULS AKT.: High LNG.: 00.10 sec

Strany 25

31Menu Quick Reference for progr. PulseCLR/ACK CLR/ACKMODEAKTIVINCMENUNEXTNEXTSETUP: POUT 1SETUP: POUT 2SETUP: POUT 3POUT 1 M ODE: P OUT

Strany 26 - +8 hours to UTC.)

32SETUP TIMECODE SETTINGS (optional)This menu lets the user select the Time codes to be generated by GPS170. Most IRIGcodes do not carry any time zone

Strany 27 - SETUP: SER. STRING TYPE

33SETUP INITIAL TIMEIf the receiver´s on-board real time clock keeps a wrong time the receiver is unable tocompute the satellites´ correct elevation a

Strany 28

34FORCE BOOT MODEThis menu lets the user force the receiver into the Boot Mode. This may be necessarywhen the satellite datas in the memory are too ol

Strany 29

35Resetting Factory DefaultsIf both the NEXT key and the INC key on the front panel are pressed while the systemis powered up the battery buffered mem

Strany 30 - TIME: 0:00:02

36Skilled/Service-Personnel only: Replacing the Lithium BatteryThe life time of the lithium battery on the board is at least 10 years. If the need ari

Strany 31 - NEXTNEXT

37Technical Specifications GPS170RECEIVER: 6 channel C/A code receiver with externalantenna/converter unitANTENNA: Antenna/converter unit with remote

Strany 32

38FREQUENCYSYNTHESIZER: 1/8 Hz up to 10 MHzACCURACY OFSYNTHESIZER: base accuracy depends on system accuracy1/8 Hz to 10 kHz Phase syncron with pulse o

Strany 33

39POWERREQUIREMENTS: 5V ± 5%, max. @1100mA (see oscilatorspecifikations)REAR EDGECONNECTOR: according to DIN 41612, type C 64, rows a+c (male)RF CONNE

Strany 34

The Menus in Detail ... 19Root Menu ...

Strany 35 - Firmware Updates

40Oscillator specificationsAccuracy of time and frequency outputs of Meinberg GPS- and DCF77 (PZF) receiverswith different oscillator optionsTCXO OCXO

Strany 36

41Technical Specifications GPS170 AntennaANTENNA: dielectrical patch antenna, 25 x 25mmreceive frequency: 1575.42 MHzbandwidth: 9 MHzCONVERTER: local

Strany 37

42Time StringsFormat of the Meinberg Standard Time StringThe Meinberg Standard Time String is a sequence of 32 ASCII characters startingwith the STX (

Strany 38

43Format of the Meinberg Capture StringThe Meinberg Capture String is a sequence of 31 ASCII characters terminated by aCR/LF (Carriage Return/Line Fee

Strany 39

44Format of the SAT Time StringThe SAT Time String is a sequence of 29 ASCII characters starting with the STX(start-of-text) character and ending with

Strany 40 - Oscillator specifications

45Format of the Uni Erlangen String (NTP)The time string Uni Erlangen (NTP) of a GPS clock is a sequence of 66 ASCIIcharacters starting with the STX (

Strany 41

46i leap second insertion‘L’ leap second is actually inserted(active only in 60th sec.)‘ ‘ (space, 20h) no leap second is insertedbbb.bbbb latitude of

Strany 42 - Time Strings

47Format of the NMEA 0183 String (RMC)The NMEA String is a sequence of 65 ASCII characters starting with the ‘$’ characterand ending with the characte

Strany 43

48Format of the ABB SPA Time StringThe ABB SPA Time String is a sequence of 32 ASCII characters starting with thecharacters ">900WD" and

Strany 44 - Format of the SAT Time String

49Format of the Computime Time StringThe Computime time string is a sequence of 24 ASCII characters starting with the Tcharacter and ending with the L

Strany 45

Resetting Factory Defaults ... 35Firmware Updates ...

Strany 46

50Time code (optional)Principle of OperationThe Board GPS170 has been designed for the generation of IRIG, AFNOR andIEEE1344 standard time codes. Apar

Strany 47

51IRIG Standard Formatx 3xTYPICAL MODULATED CARRIER IRIG-A : 10000 HzIRIB-B : 1000 Hzbinary 0 binary 1

Strany 48

52AFNOR Standard Format

Strany 49

53Assignment of CF Segment in IEEE1344 modeBit No. Designation Description49Position Identifier P550 Year BCD encoded 1low nibble of BCD encoded year5

Strany 50 - Block Diagram Time code

54Generated Time codesBesides the amplitude modulated sine wave signal, the board also provides unmodula-ted DC-Level Shift TTL output in parallel. Th

Strany 51 - IRIG Standard Format

55ded at the VG64-Connector, i.e. if code B132 is selected also code B002 is available.This applies for the codes AFNOR NFS 87-500 and IEEE1344 as wel

Strany 52 - AFNOR Standard Format

56Signal Description GPS170Name Pin FunctionGND 32a+c GroundVCC in (+5V) 1a+c +5V supplyVCC in (+12V) 2a+c +12V supplyVCC in (+5V) 3a+c +5 V supply (T

Strany 53 - Position Identifier P5

57Rear Connector Pin Assignments GPS170ac1 VCC in (+5V) VCC in (+5V)2 VCC in (+12V) VCC in (+12V)3 VDD in (TCXO/OCXO) VDD in (TCXO/OCXO)4 (reserved,

Strany 54 - Generated Time codes

58Menu Quick Reference GPS170LCD-MPNEXTCLR/ACKMENUNEXTMeinberg GPS170 S/N: 0290100xxx70REV:1.xx LCD_2GPS: NORMAL OPERATION Mon, DD.

Strany 55 - Technical Data

59Technical appendix

Strany 56 - Signal Description GPS170

Technical appendix ... 59Technical Specifications GPS170LCD-MP ...

Strany 57

60Technical Specifications GPS170LCD-MPHOUSING: Metal desktop case, MULTIPAC SchroffFront panel: 1 U / 84 HP (43.6 mm high / 426.4 mm wide)PROTECTIONR

Strany 58

61Rear View GPS170LCD-MPPULSE OUTPUT COM-1 COM-0TIME CAPTURE RS-232 RS-232ANTENNA100 ... 240V AC50/60 Hz 165916591659

Strany 59 - Technical appendix

62Pin Assignments of the SUB-D Connectors165916591659Connector Assignments Error Relais (Time Sync)Relay on (pin. 7+8 are closed), if synchronization

Strany 60 - CE Label

63Technical Specifications Power Supply T-60BINPUT: 85 ... 264V AC, 47 ... 63Hz, 1A/230V, 2A/115VFUSE: elektronicCURRENTLIMITING: 105 - 150% Iout nomO

Strany 62 - . antenna faulty)

65The GPSMON32 Configuration and Monitoring ApplicationThe program GPSMON32 can be used to monitor and configure all essentialfunctions of Meinberg GP

Strany 63

66Online HelpThe online help can be started by clicking the menu item 'Help' in menu Help. In everyprogram window a direct access to a relat

Strany 64

67Diskette with Windows Software GPSMON32

Strany 65 - Network Connection

GPS170_LCD- MP- E- 311007

Strany 66 - Online Help

General InformationThe satellite receiver clock GPS170 has been designed to provide extremly precisetime to its user. The clock has been developed for

Strany 67

8The Modular System GPS170LCD-MPGPS170LCD-MP GPS-Receiver is a set of equipment composed of a satellite control-led clock GPS170 together with a power

Strany 68 - GPS170_LCD- MP- E- 311007

9GPS170 FeaturesThe front panel integrates a 2 x 40 character LC display, two LED indicators and fivepush buttons. The receiver is connected to the an